Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 586

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> OPTION> IMG-MCON
PRESTART
Setting to extend initial rotation time
Lv.2 Details
To set whether to extend the time from start of initial rotation to image
formation.
When hue is not stable at the start of printing, engine can be stable
by extending the initial rotation time.
Use case
When hue is not stable at the time of printing in first few sheets
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 5
Unit
2 seconds
Default value
0
CL-RDCTN
High compress PDF TX clr reduct mode
Lv.1 Details
To set whether to execute the color reduction processing mode at
high compression PDF (text mode) transmission.
Set 1 when image quality is deteriorated at high compression PDF
(text mode) transmission. Image quality is improved by executing the
color reduction processing mode.
Use case
Upon user's request (improvement of image quality)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
5
5-358
■ IMG-SPD
ARC-INT1
Lv.2 Details
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
Unit
Appropriate target value 100
Default value
Related service mode
ARC-INT2
Lv.2 Details
T-5-66
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Display/adj/set range
Unit
Appropriate target value 25
Default value
Related service mode
COPIER> OPTION> IMG-SPD
Set of ARCDAT interruption interval
To set the number of sheets as the intervals at which ARCDAT
control is executed.
When the number of sheets reaches the specified value, ARCDAT
control is executed by interrupting an ongoing job.
If the value is too large, the density of image becomes different
before and after the interruption.
If the value is too small, the productivity is lowered.
Actual setting value is calculated by dividing the entry value by 0.9
and rounding up after the decimal points. (e.g.: If an entry value is
100, setting value will be 122.)
5 to 1000
1 sheet
0
COPIER> OPTION> IMG-LSR> ARC-INT2
Set ARCDAT exe interval: last rotation
To set the number of sheets which ARCDAT control is not executed,
from the start of a job.
ARCDAT control which is supposed to be executed during the
specified number of sheets is executed at last rotation of the previous
job. Since the number of interruptions during a job is reduced, the
productivity is enhanced.
However, the number of times of ARCDAT control executed at last
rotation might be increased depending on the print conditions.
Actual setting value is calculated by dividing the entry value by 0.9
and rounding up after the decimal points. (e.g.: If an entry value is
25, setting value will be 28.)
Do not set a larger value than ARC-INT1.
5 to 1000
1 sheet
0
COPIER> OPTION> IMG-LSR> ARC-INT1