COPIER> ADJUST> HV-PRI
OFSTACY2
Adjust Y charge AC voltage (1/2 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for Y at 1/2 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACM2, OFSTACC2
OFSTACM2
Adjust M charge AC voltage (1/2 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for M at 1/2 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACY2, OFSTACC2
OFSTACC2
Adjust C charge AC voltage (1/2 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for C at 1/2 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACY2, OFSTACM2
COPIER> ADJUST> HV-PRI
OFSTACY3
Adjust Y charge AC voltage (1/3 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for Y at 1/3 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACM3, OFSTACC3
OFSTACM3
Adjust M charge AC voltage (1/3 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for M at 1/3 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACY3, OFSTACC3
OFSTACC3
Adjust C charge AC voltage (1/3 speed)
Lv.1 Details
To adjust the offset of the charge AC voltage for C at 1/3 speed.
As the value is incremented by 1, the offset is increased by 20 Vpp.
Increase the value when the density is low and decrease the value
when the density is high or a spotted image occurs.
Use case
• At the occurrence of an image density failure
• At the occurrence of a spotted image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-20 to 20
Unit
20 Vpp
Default value
0
Related service mode
COPIER> ADJUST> HV-PRI> OFSTACY3, OFSTACM3