Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 461

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> ADJUST> HV-TR
TR-ENV4
Sec trns indiv setting environment:set 4
Lv.2 Details
To set the environment (absolute moisture amount) for setting 4.
Setting 4 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV4,
TR-PPR4, TR-CLR4 and TR-DUP4. When this condition is satisfied,
the target current that is set in 2TR-TGT4 and paper allotted voltage
that is set in 2TR-SHR4 are applied to the Secondary Transfer Outer
Roller.
Use case
When an image failure that differs due to the environment occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 3
1: Low humidity (Absolute moisture amount: 5.8g/m3 and less)
2: Normal humidity (5.9 to 15g/m3)
3: High humidity (15.1g/m3 and more)
Default value
2
Related service mode
COPIER> ADJUST> HV-TR> TR-PPR4, TR-CLR4, TR-DUP4, 2TR-
TGT4, 2TR-SHR4
TR-ENV5
Sec trns indiv setting environment:set 5
Lv.2 Details
To set the environment (absolute moisture amount) for setting 5.
Setting 5 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV5,
TR-PPR5, TR-CLR5 and TR-DUP5. When this condition is satisfied,
the target current that is set in 2TR-TGT5 and paper allotted voltage
that is set in 2TR-SHR5 are applied to the Secondary Transfer Outer
Roller.
Use case
When an image failure that differs due to the environment occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 3
1: Low humidity (Absolute moisture amount: 5.8g/m3 and less)
2: Normal humidity (5.9 to 15g/m3)
3: High humidity (15.1g/m3 and more)
Default value
2
Related service mode
COPIER> ADJUST> HV-TR> TR-PPR5, TR-CLR5, TR-DUP5, 2TR-
TGT5, 2TR-SHR5
COPIER> ADJUST> HV-TR
TR-ENV6
Sec trns indiv setting environment:set 6
Lv.2 Details
To set the environment (absolute moisture amount) for setting 6.
Setting 6 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV6,
TR-PPR6, TR-CLR6 and TR-DUP6. When this condition is satisfied,
the target current that is set in 2TR-TGT6 and paper allotted voltage
that is set in 2TR-SHR6 are applied to the Secondary Transfer Outer
Roller.
Use case
When an image failure that differs due to the environment occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 3
1: Low humidity (Absolute moisture amount: 5.8g/m3 and less)
2: Normal humidity (5.9 to 15g/m3)
3: High humidity (15.1g/m3 and more)
Default value
2
Related service mode
COPIER> ADJUST> HV-TR> TR-PPR6, TR-CLR6, TR-DUP6, 2TR-
TGT6, 2TR-SHR6
TR-ENV7
Sec trns indiv setting environment:set 7
Lv.2 Details
To set the environment (absolute moisture amount) for setting 7.
Setting 7 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV7,
TR-PPR7, TR-CLR7 and TR-DUP7. When this condition is satisfied,
the target current that is set in 2TR-TGT7 and paper allotted voltage
that is set in 2TR-SHR7 are applied to the Secondary Transfer Outer
Roller.
Use case
When an image failure that differs due to the environment occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 3
1: Low humidity (Absolute moisture amount: 5.8g/m3 and less)
2: Normal humidity (5.9 to 15g/m3)
3: High humidity (15.1g/m3 and more)
Default value
2
Related service mode
COPIER> ADJUST> HV-TR> TR-PPR7, TR-CLR7, TR-DUP7, 2TR-
TGT7, 2TR-SHR7
5
5-233