COPIER> ADJUST> HV-TR
2TR-TGT8
Sec trns indiv set target currnt: set 8
Lv.2 Details
To adjust the target current of secondary transfer for setting 8.
Setting 8 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV8,
TR-PPR8, TR-CLR8 and TR-DUP8. When this condition is satisfied,
the target current that is set here is applied to the Secondary
Transfer Outer Roller.
When low-voltage mottled image or toner scattering on solid image
occurs, increase the current.
When high-voltage mottled image or density loss due to excessive
transfer occurs, decrease the current.
As the value is incremented by 1, the current changes by 2 uA.
+: Increase
-: Decrease
Use case
When an image failure occurs on all paper types (mottled image,
density loss due to excessive transfer, toner scattering on solid
image, etc.)
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Increase/decrease the value by 1 while checking the symptom each
time.
Display/adj/set range
-10 to 10
Unit
2 uA
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> TR-ENV8, TR-PPR8, TR-CLR8, TR-
DUP8, 2TR-SHR8
2TR-SHR1
Sec trns indiv set ppr allot voltg:set 1
Lv.2 Details
To adjust the paper allotted voltage of secondary transfer for setting 1.
5
Setting 1 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV1,
TR-PPR1, TR-CLR1 and TR-DUP1. When this condition is satisfied,
the paper allotted voltage that is set here is applied to the Secondary
Transfer Outer Roller.
As the value is incremented by 1, the voltage changes by 100V.
+: Increase
-: Decrease
Use case
When an image failure that differs due to the paper type occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Increase/decrease the value by 1 while checking the symptom each
time.
Display/adj/set range
-10 to 10
Unit
100 V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> TR-ENV1, TR-PPR1, TR-CLR1, TR-
DUP1, 2TR-TGT1
5-226
COPIER> ADJUST> HV-TR
2TR-SHR2
Sec trns indiv set ppr allot voltg:set 2
Lv.2 Details
To adjust the paper allotted voltage of secondary transfer for setting 2.
Setting 2 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV2,
TR-PPR2, TR-CLR2 and TR-DUP2. When this condition is satisfied,
the paper allotted voltage that is set here is applied to the Secondary
Transfer Outer Roller.
As the value is incremented by 1, the voltage changes by 100V.
+: Increase
-: Decrease
Use case
When an image failure that differs due to the paper type occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Increase/decrease the value by 1 while checking the symptom each
time.
Display/adj/set range
-10 to 10
Unit
100 V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> TR-ENV2, TR-PPR2, TR-CLR2, TR-
DUP2, 2TR-TGT2
2TR-SHR3
Sec trns indiv set ppr allot voltg:set 3
Lv.2 Details
To adjust the paper allotted voltage of secondary transfer for setting 3.
Setting 3 is the combination condition of environment, paper type
(paper weight), color mode and feed side that are set in TR-ENV3,
TR-PPR3, TR-CLR3 and TR-DUP3. When this condition is satisfied,
the paper allotted voltage that is set here is applied to the Secondary
Transfer Outer Roller.
As the value is incremented by 1, the voltage changes by 100V.
+: Increase
-: Decrease
Use case
When an image failure that differs due to the paper type occurs
(mottled image/density loss due to excessive transfer/toner scattering
on solid image)
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Increase/decrease the value by 1 while checking the symptom each
time.
Display/adj/set range
-10 to 10
Unit
100 V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> TR-ENV3, TR-PPR3, TR-CLR3, TR-
DUP3, 2TR-TGT3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents