Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 369

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

Address
bit
Name
P007
15
Fixing Motor_FG
14
Fixing Motor_LOCK
13
Not used
12
Not used
11
Not used
10
Not used
9
Not used
8
Not used
7
Reserve
6
Reserve
5
Duplex Left Motor Current
Switch 1
4
Duplex Left Motor Current
Switch 0
3
Duplex Right Motor Current
Switch 1
2
Duplex Right Motor Current
Switch 0
1
Registration Motor Current
Switch 1
0
Registration Motor Current
Switch 0
Symbol
Remarks
M48
Input value of the clock synchronized
with rotation of the Fixing Motor
Frequency= number of rotation x
50/60
M48
0: Number of rotation is within +/-
6.25%
1: Motor stop
M32
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M32
1/0: Drive current B
1/1: Drive current C
M33
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M33
1/0: Drive current B
1/1: Drive current C
M34
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M34
1/0: Drive current B
1/1: Drive current C
Address
bit
Name
P008
15
Pre-fixing Feed Motor Current
Switch 1
14
Pre-fixing Feed Motor Current
Switch 0
13
Fixing Belt Displacement
Control Motor Current Switch 1
12
Fixing Belt Displacement
Control Motor Current Switch 0
11
Fixing Pressure Release Motor
Current Switch 1
10
Fixing Pressure Release Motor
Current Switch 0
9
Pressure Belt Displacement
Motor Current Switch 1
8
Pressure Belt Displacement
Motor Current Switch 0
7
Reserve
6
Duplex Left Motor Phase
Pattern Switch
5
Pre-fixing Feed Motor Phase
Pattern Switch
4
Duplex Right Motor Phase
Pattern Switch
3
Registration Motor Phase
Pattern Switch
2
Fixing Belt Displacement
Control Motor Pattern Switch
1
Fixing Belt Pressure Release
Motor Phase Pattern Switch
0
Pressure Belt Displacement
Control Motor Phase Pattern
Switch
Symbol
Remarks
M35
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M35
1/0: Drive current B
1/1: Drive current C
M46
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M46
1/0: Drive current B
1/1: Drive current C
M47
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M47
1/0: Drive current B
1/1: Drive current C
M49
I1/I0
0/0: HOLD_OFF
0/1: Drive current A
M49
1/0: Drive current B
1/1: Drive current C
M32
1: 2phase, 0: 1-2phase
M35
1: 1-2phase, 0: 2phase
M33
1: 2phase, 0: 1-2phase
M34
1: 2phase, 0: 1-2phase
M46
1: 2phase, 0: 1-2phase
M47
1: 1-2phase, 0: 2phase
M49
1: 2phase, 0: 1-2phase
5-141