E
Detailed
Occurance
Items
code
code
area
E001 -0002
-05
Title
Description
of detection
Measures
E001 -0003
-05
Title
3
Description
of detection
Measures
3-4
Description
Abnormal temperature rise of fixing subthermistor 1
(THM1-2) (circuit failure)
Fixing subthermistor 1 (THM1-2) sensed an abnormal
high temperature. (ASIC detection)
Check the detection temperature of the fixing sub
thermistor 1 (THM1-2) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UE).
A. In case that the detection temperature is 250 degC
A-1. The cable of the fixing sub thermistor 1 is
caught -> replace the fixing belt unit
B. In case that the detection temperature is other than
250 degC
B-1. Location of the fixing main thermistor is
inappropriate -> replace the fixing belt unit
B-2. Replace the DC controller PCB
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Abnormal temperature rise of fixing subthermistor 2
(THM1-3) (circuit failure)
Fixing subthermistor 2 (THM1-3) sensed an abnormal
high temperature. (ASIC detection)
Check the detection temperature of the fixing sub
thermistor 2 (THM1-3) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UE2).
A. In case that the detection temperature is 250 degC
A-1. The cable of the fixing sub thermistor 2 is
caught -> replace the fixing belt unit
B. In case that the detection temperature is other than
250 degC
B-1. Location of the fixing main thermistor is
inappropriate -> replace the fixing belt unit
B-2. Replace the DC controller PCB
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E
Detailed
Occurance
Items
code
code
area
E001 -0011
-05
Title
Fixing main thermistor abnormal temperature rise (circuit
abnormality)
Description
Fixing main thermistor (THM1-1) detected abnormal high
of detection
temperature. (software detection)
Measures
Check the detection temperature of the fixing main
thermistor (THM1-1) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UC).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E001 -0012
-05
Title
Fixing sub thermistor 1 (THM1-2) abnormal temperature
rise (circuit abnormality)
Description
Fixing sub thermistor 1 (THM1-2) detected abnormal
of detection
high temperature. (software detection)
Measures
Check the detection temperature of the fixing sub
thermistor 1 (THM1-2) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UE).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
A-1. The cable of the fixing main thermistor is
caught -> replace the fixing belt unit
250 degC
B-1. Replace the DC controller PCB
A-1. The cable of the fixing sub thermistor 1 is
caught -> replace the fixing belt unit
250 degC
B-1. Location of the fixing main thermistor is
inappropriate -> replace the fixing belt unit
B-2. Replace the DC controller PCB