Writing/Reading The Data Using The Nc Data Designation - Mitsubishi Electric MELDAS 600M Series Instruction Manual

Table of Contents

Advertisement

5.5.1 Writing/reading the data using the NC data designation

When reading the Process parameter "330002 Base axis", the following data is set.
Basic system : System No.1
Object No.
Item No.
(1) Setting the data
(2) Reading the data
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
: 33
: 2
1)
Using the cursor keys, move
the cursor to the "Addr."
position.
2)
Set the address.
1
INPUT
3)
Separate the Object No.,
Item No. and Data No. with a
"/", and set.
33/2/1
INPUT
4)
Press the menu key
.
Data write
5)
Set the data, and press the
key.
INPUT
1)
Set the address, object No.,
item No. and data No. in the
same way as step (1).
2)
Press the menu key
.
Data read
(Note) The cursor is constantly displayed. Using the cursor keys, the cursor can be moved
to the Addr area, OBJ/Item/Data area and Size area.
search engine
5. Diagnosis Screens
Data No.
: 1
Size
: (No setting)
The written contents appear.
The cursor moves to the "Addr." position.
Addr
OBJ / Item / Data
1
12345678
2
12345678
999/ 100/99999 4
3
12345678
4
12345678
The index No. is highlighted, and the set value is
displayed.
The cursor moves to the right item position.
The set value appears.
The cursor moves to the right item position.
Write processing is executed.
The Index No. highlight returns to normal.
The index No. highlight is released, and the normal
display of the memory data starts.
The data format (data size, display format) of the data
displayed in the memory data differs according to the
data type to be displayed.
I – 279
Size
1/99999/
1 48
8
4

Advertisement

Table of Contents
loading