(2) Operation during manual/automatic simultaneous operation
(a) The manual operation and automatic operation feedrates are independent. The acceleration/
(b) The rapid traverse override is valid for both automatic operation and manual operation. The
(c) Manual interlock is valid for the manual/automatic simultaneous valid axis, and automatic
(d) Manual machine lock is valid for the manual/automatic simultaneous valid axis, and automatic
(e) The signals in cutting feed and in rapid traverse will follow the automatic operation movement
(f) Movement of the manual/automatic simultaneous valid axis will not stop with the single block
(g) If the manual/automatic simultaneous valid axis reaches the stored stroke limit or stroke limit,
(h) Even if the automatic operation handle interrupt option is added and the handle mode is
(i)
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
deceleration mode (rapid traverse/cutting feed) and time constants are also independent.
cutting feed override and 2nd cutting feed override are valid only for automatic operation.
However, these will also be valid during manual operation if the manual override valid signal is
ON. Override cancel is valid only for automatic operation.
interlock is valid for the axis in automatic operation.
machine lock is valid for the axis in automatic operation.
mode.
stop or feed hold stop.
the axis moving in automatic operation will also stop immediately, and the feed hold state will
be entered. In this case, automatic operation can be restarted by canceling the stored stroke
limit or stroke limit with manual operation.
selected for the manual operation mode, the manual/automatic simultaneous function will be
the priority for the axis for which the "manual/automatic simultaneous valid" signal is ON.
The speed display indicates the following speeds according to the actual feedrate display
parameter (base system #120040).
Manual/automatic
simultaneous
operation
Only manual operation
Only automatic
operation
search engine
For actual feedrate display 1
Composite manual and
automatic speeds
(The actual feedrates are
independent.)
Manual actual feedrate
Automatic actual feedrate
II – 33
For actual feedrate display 0
Automatic F command speed
priority
(Manual command speed when
there is no axis moving with
automatic operation)
Manual command speed
Automatic F command speed