Operation State; Operation State Transition Diagram; Power Off - Mitsubishi Electric MELDAS 600M Series Instruction Manual

Table of Contents

Advertisement

1. Operation State

1.1 Operation state transition diagram

The NC unit operation state changes momentarily according to the program contents or signals from
the operation panel or machine. The controller roughly classifies the operation state into power off,
not ready, and ready.
NC operation is enabled only in the operating preparation ready state. The operating preparation
ready state is furthermore classified into reset, automatic operation stop, automatic operation start,
and automatic operation pause as shown below:
Manual mode operation is enabled in the operation complete state.
Operations not ready state
Operations not ready state

1.2 Power OFF

The power OFF state means that no power is supplied to the control circuit.
(1) From any other state to power OFF (transition (1))
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
Power OFF state
Waiting for READY ON
READY ON
5
Reset operations
In automatic operations
Automatic operation
is stopped
Automatic
Feed hold
7
6
operation
is started
Automatic operation
in progress
Automatic
Block
operation
8
6
stop
is started
Automatic operation is
stopped
• When the POWER OFF switch of the setting and display unit is pressed.
• When POWER OFF signal is input from the machine.
• When power supplied from the machine to NC unit is turned OFF.
search engine
1. Operation State
1
NC power OFF
NC power ON
2
Failure in operating preparations
(Emergency stop)
Problem is resolved
4
4
Reset process
Finished
Reset
processing
5
Start
6
M02/M30
During operation of the above, automatic start is not possible.
II – 2
Emergency stop
3
Resolve problem that
caused emergency stop
5
Reset operations
Screen operations
(Machinery preparation)
Searching unmodal
Restart searching
Input
Screen operation (simulation)
completed
Checking program
Calculating machining
time

Advertisement

Table of Contents
loading