CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
(3) #1 to interruption point
4) First, the axes other than that designated in parameter "ret1" simultaneously move.
5) Next, the axes designated in parameter "ret1" move simultaneously.
3)
#1
4)
Setting the parameters "ret1" and "ret2"
The return type parameters are set with the base common parameters "110011 ret1" and
"110012 ret2".
Set the axis to be moved as a bit unit in "ret1" and "ret2".
The axes designated with "ret1" move to the interruption point as shown with 5) in the drawing.
The non-designated axes move as shown with 4) in the drawing.
The axes designated with "ret2" move to the #2 transit point shown as 2) in the drawing, while
the non-designated axes move as shown with 1).
The parameter details are as shown below.
7 6 5 4 3 2 1 0
ret1
Transit point #1 1st axis
Transit point #1 2nd axis
Transit point #1 3rd axis
Transit point #1 4th axis
Transit point #1 5th axis
Transit point #1 6th axis
Transit point #1 7th axis
Transit point #1 8th axis
search engine
Return start point
1)
2)
#2
5)
Interruption point
ret2
II – 48
Return path
Retract path
1st transit point
#1
2nd transit point
#2
7 6 5 4 3 2 1 0
Transit point #2 1st axis
Transit point #2 2nd axis
Transit point #2 3rd axis
Transit point #2 4th axis
Transit point #2 5th axis
Transit point #2 6th axis
Transit point #2 7th axis
Transit point #2 8th axis