3.8 Auxiliary axis system alarms (AZ
AZ0070
Alarm
infor-
mation
0001
0002
0003
AZ0071
Alarm
infor-
mation
0001
Downloaded from
ManualsNet.com
Appendix 3. Alarm Messages
Aux axis ABS position error
Details
Zero point
The zero point has not been
initialization
initialized in the absolute position
incomplete
system.
Absolute
The absolute position coordinate
position data
data in the amplifier has been lost.
lost
Absolute
The absolute position system
position system
related parameters have been
related
changed or lost.
parameter error
Aux axis drop voltage
Details
Absolute
The data in the detector has been
position
lost due to battery voltage drop.
detector data
Battery voltage drop
lost
Detector cable wire breakage or
looseness
search engine
CHAPTER 4 APPENDICES
)
IV – 52
Remedy
• Initialize the zero point.
• Initialize the zero point.
• Correctly set the parameters and
then initialize the zero point.
Remedy
• Check the battery and detector
cable and then initialize the zero
point.