Mitsubishi Electric MELDAS 600M Series Instruction Manual page 110

Table of Contents

Advertisement

2.7.3 Erasing common variables
(1) Erasing the contents of variable (102 to 104)
(2) Erasing the comment of variable (509)
(3) Notes for erasing common variables
1)
2)
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
2. Monitor (Operation) Screens
1)
Press the menu key
Varibl clear .
2)
Set the No. (range) of the
variable to be erased in the
data setting area, and press
the
key.
INPUT
102/104
INPUT
To erase only one variable, set
the variable No. only.
102
INPUT
3)
Press the
key.
Y
1)
Press the menu key
.
Comment clear
2)
Select the variable in the
same manner as for item (1)
above, and press the
key.
509
INPUT
3)
Press the
key.
Y
If the Control parameter "310004 Com-var RST clear" is ON, the common variable data is
cleared when reset. If the Control parameter "310005 Com-var PWR-ON" is ON, the common
variable data is cleared when the power is turned ON.
The variable at the cursor position will become the target of the erasing if the
pressed without designating a variable No.
search engine
The menu is highlighted.
A message confirming the erasing appears.
The selected variable is erased.
Vrbl Details
Comment
102
103
104
105
-10.0000
106
0.0005
107
-123456.7890
108
-1.2345 E-10
109
0.0000
110
0.0000
111
100.0000
112
-10.0000
113
0.0005
114
-123456.7890
115
-1.2345 E-10
The menu is highlighted.
A message confirming the erasing appears.
INPUT
Only the 509 comment is erased.
The variable contents are not erased.
I – 95
key is
INPUT

Advertisement

Table of Contents
loading

Table of Contents