(1) Stored stroke limit II (When prohibited range is outside)
Used with the stored stroke limit I function, the confined range designated by the two functions
becomes the moveable range.
(2) Stored stroke limit IIB (When prohibited range is inside)
A range besides the stored stroke limit I becomes the movement prohibited range.
(3) Setting with program commands
With the stored stroke limit II (IIB) function, the prohibited range (parameters) can be changed
and this function can be turned ON and OFF with the program commands. Refer to the section on
the program parameters inputs in the Programming Manual, and the Parameter Manual for details.
Downloaded from
ManualsNet.com
CHAPTER 3 MAINTENANCE
6. Setting the Stored Stroke Limit
Machine coordinate
system
Range prohibited
Machine moveable
with stored
range
stroke limit II
Point 3
Point 1
-
Point 4
Machine coordinate
system
Range prohibited
with stored
Machine movement
stroke limit IIB
valid range
Point 3
-
Point 1
+ setting value
search engine
Point 2
Point 4
setting value
+ setting value
Point 2
setting value
III – 32
The following values are set with
the coordinate values in the
machine coordinate system:
Point 3: 340008 soft limit (–)
Point 4: 340009 soft limit (+)
The area determined by points 1
and 2 is the prohibited range set
with stored stroke limit I.