No.
16 0027 Servo function 1
13 0013 Backlash for G1
13 0012 Backlash for G0
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
Name
For MDS-B-SVJ2
Select the servo functions.
aflt zrn2
bit
(Note) Set "0" in bits with no particular description.
LMC type
The lost motion compensation type for 160027
servo function 1 bit 8 and 9 (1mc1, 1mc2) is
displayed.
Set the backlash compensation amount with
movement command in the cutting feed mode
or with reverse direction in the manual mode.
Set the backlash compensation amount with
movement command in rapid traverse mode or
with reverse direction in manual mode.
Note that "G1back" is used for the movement in
the handle mode.
search engine
3. Setup Screens
Details
(Continued from the
previous page.)
F
E
D
C
B
ovs2 ovs1 lmc2 lmc1
7
6
5
4
3
vfct2 vfct1
Name
Meaning when set to 0
0
1
2
3
4
vfct1
00: Jitter compensation invalid
01: Jitter compensation 1 pulse
5
vfct2
10: Jitter compensation 2 pulse
11: Jitter compensation 3 pulse
6
7
8
lmc1
Set the compensation gain with SV016 (LMC1) and SV041 (LMC2).
00: Lost motion compensation invalid
9
lmc2
01: Lost motion compensation type 1
10: Lost motion compensation type 2
11: Reserved
A
ovs1
00: Overshoot compensation invalid
01: Overshoot compensation type 1
B
ovs2
10: Overshoot compensation type 2
11: Overshoot compensation type 3
C
D
E
zrn2
Set "1".
F
aflt
Adaptive filter stop
I – 227
Setting range (units)
0000 to FFFF
HEX setting
A
9
8
2
1
0
Meaning when set to 1
Adaptive filter start
(Display-only)
(Blank):
Compensation type
invalid
TYPE1:
Compensation type 1
TYPE2:
Compensation type 2
–99999 to 99999
(Interpolation unit)
–99999 to 99999
(Interpolation unit)