3.5.4 Input/Output Parameter screen (I/O param screen)

The necessary parameters are set when transferring files between differing devices. Parameters with a
" " mark added are validated after restarting.
Number
35 0001
35 0002
35 0003
35 0004
35 0005
35 0006
35 0007
35 0008
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
Name
Data input
This sets the I/O port No. and device No. when each
port No.
file of machining program, tool data, parameters,
etc., is input from the external device to the NC
Data input
memory.
dev No.
Data output
This sets the I/O port No. and device No. when each
file of machining program, tool data, parameters,
port No.
etc., is output from the NC memory to the external
Data output
device.
dev No.
NC oper port
This sets the I/O port No. and device No. when the
No.
RS-232C is operating.
NC oper dev
No.
Macro print
This sets the I/O port No. and device No. of the
port No.
output device when carrying out an external output
command in the user macro.
Macro print
dev No.
search engine
3. Setup Screens
Details
I – 163
Setting range (units)
<Port>
M6A: 1 to 2
M6B: 1 to 2
1 : Port 1
2 : Port 2
<Device>
1 : Device No. <1>
4 : Device No. <4>
<Port>
M6A : 1 to 2
M6B : 1 to 2
<Device>
1 : Device No. <1>
4 : Device No. <4>
<Port>
M6A : 1 to 2
M6B : 1 to 2
1 : Port 1
2 : Port 2
<Device>
1 : Device No. <1>
4 : Device No. <4>

Advertisement