6. Setting the Stored Stroke Limit
(1) Outline
Three tool entry prohibited ranges can be set with the stored stroke limit I, the stored stroke limit II
(IIB) and the stored stroke limit IB. Part of the prohibit range on the outside of the soft limit I can
be validated with the stored stroke limit IC.
If a tool tries to move past the set range, an alarm will occur, and the axis will decelerate to a stop.
If the prohibited range is entered and an alarm occurs, movement will be possible only in the
direction opposite the entry direction.
Downloaded from
ManualsNet.com
CHAPTER 3 MAINTENANCE
6. Setting the Stored Stroke Limit
Stored stroke limit IB
Stored stroke limit IIB
Stored stroke limit I
Stored stroke limit IC
search engine
Stored stroke limit IC
III – 28
Prohibited range
Moveable range