Mitsubishi Electric MELDAS 600M Series Instruction Manual page 419

Table of Contents

Advertisement

6.3 Stored stroke limit IB
The boundary is set for each axis with the parameters (axis parameters "340025 OT_IB–" and "340026
OT_IB+". The inside of the set boundary is the prohibited range.
This is valid when the axis specification parameter "130027 IB_off" is set to "0".
Downloaded from
ManualsNet.com
CHAPTER 3 MAINTENANCE
6. Setting the Stored Stroke Limit
Point 4
Range prohibited
Point 6
with stored
stroke limit IIB
Machine movement
valid range
Point 3
-
setting value
Point 1
search engine
Point 2
Point 6
Machine
coordinate
system
+ setting value
III – 33
The following values are set with the
coordinate values in the machine
coordinate system:
Point 5: 340025 OT_IB–
Point 6: 340026 OT_IB+
The area determined by points 1 and
2 is the prohibited range set with
stored stroke limit I, and the area
determined by points 3 and 4 is the
one with stored stroke limit IIB.