No.
0061
0062
0063
0064
0065
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
Details
Reference
Automatic/manual operation was
point return
started before reference point return
incomplete.
was executed with the incremental
Starting not
system.
possible.
In initializing
The start signal was input while
absolute
initializing the absolute position.
point.
Starting not
possible.
In absolute
The start signal was input during an
position
absolute position alarm.
alarm.
Starting not
possible.
In random
The manual operation mode was
positioning
started during the random
mode.
positioning mode.
Manual
operation not
possible.
Uneven
The commanded station No. was
indexing
higher than 8 during uneven
station No.
indexing.
illegal.
Starting not
possible.
search engine
• Execute the reference point
return.
• Complete the absolute position
initialization.
• Initialize the absolute position and
then fix the absolute position
coordinates.
• Turn the random positioning
mode OFF before switching to the
manual operation mode.
• Check the commanded station
No.