Mitsubishi Electric MELDAS 600M Series Instruction Manual page 355

Table of Contents

Advertisement

6.10 Optional block skip
When the OPTIONAL BLOCK SKIP switch is turned ON, a block which begins with a slash ( / ) is
skipped; when the switch is OFF, the block is executed. This enables the operator to specify
whether or not a block beginning with a slash ( / ) code is executed.
(Example) To work two parts as illustrated below, if the following program is prepared and work is
Program N1G54 ;
Downloaded from
ManualsNet.com
CHAPTER 2 MACHINE OPERATIONS
6. Operation Switch Functions and Other Functions
made by turning ON the OPTIONAL BLOCK SKIP switch, part (1) is provided; if work is
made by turning OFF the switch, part (2) is provided:
N2G90G81X50. Z-20. R3. F100 ;
/N3X30. ;
N4X10. ;
N5G80 ;
M02 ;
Part (1)
Switch ON
search engine
Part (2)
Switch OFF
II – 22