3.7 Auxiliary axis servo alarms (AS
AS0001
Alarm
infor-
mation
0011
0013
0016
0017
0025
0034
0036
0037
0038
0039
Downloaded from
ManualsNet.com
Appendix 3. Alarm Messages
Aux axis sevo alarm 1
Details
PCB error
An error occurred in the amplifier's
internal PCB.
Software
An error occurred in the amplifier's
processing
internal reference clock.
timeout, clock
error
Motor type,
Motor type error
detector type
error
Detector initial communication error.
Detector CPU error
PCB error
An error occurred in the amplifier's
(A/D conversion
internal A/D converter.
initial error)
Absolute
An error occurred in the detector's
position lost
internal absolute position data.
CRC error
An error occurred in the
communication with the NC.
Timeout, NC
Communication with the NC was cut
power down
off.
Parameter error
The parameter setting value is
(regenerative
incorrect.
resistor type
error)
Communication
An error occurred in the
frame error
communication with the NC.
Communication
Undefined data was transferred
INFO error
from the NC.
search engine
CHAPTER 4 APPENDICES
)
IV – 48
Remedy
• Replace servo amplifier.
• Replace servo amplifier.
• Use a correct amplifier and motor
combination.
• Connect correctly.
• Replace the motor.
• Replace or repair cable.
• Replace the motor (detector).
• Replace servo amplifier.
• Turn the power ON for 2 to 3
minutes while the alarm is
occurring, and then turn the power
ON again.
• Replace the battery, and initialize
the absolute position again.
• Take countermeasures against
noise.
• Connect correctly.
• Turn the NC power ON.
• Replace the amplifier or NC.
• Set the parameter correctly.
• Take countermeasures against
noise.
• Change the NC software version
to a compatible version.