No.
OPW0123 Machining time
OPW0124 In synchronous
OPW0125 In axis control
OPW0126 Acc/dec T cnst
OPW0127 In emergency
OPW0128 In absolute
OPW0129 In abs posn
OPW0130 Tool life over
OPW0131 Overheat
OPW0132 Top search not
OPW0133 Restart search
OPW0134 Restart search
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
Message
Starting was attempted during
calculate mode
the machining time calculation
or during the machining time
calculation mode.
The synchronous correction
correction mode
mode switch was turned ON in a
mode other than the handle
mode.
Starting is not possible because
the axis is already being
controlled.
An internal interlock occurred
pre-intrpl large
because the pre-interpolation
acceleration/deceleration time
constant is too large.
Starting was attempted during
stop
an emergency stop.
Starting was attempted during
position alarm
an absolute position detection
alarm.
Starting was attempted during
initial setting
zero point initialization of the
absolute position detection
system.
The tool life (No. of uses, time,
etc.) has reached the setting
value.
The NC or operation board
temperature has risen above the
specified range.
A top search was not executed
completed
before the restart search.
In internal error occurred during
error
the restart search.
Another restart search was
completed
attempted in the program restart
after the restart search was
completed.
search engine
Details
• Wait for the machining time
calculation to complete, or restart
after canceling the machining time
calculation by resetting.
• Select the handle mode.
• Turn OFF the synchronous
correction mode switch.
• Restart after stopping the axis
being controlled.
• Reduce the command speed, or
reduce the parameter setting
value for the pre-interpolation
acceleration/deceleration time
constant.
• Restart after canceling the
emergency stop.
• Start after canceling the absolute
position detection alarm.
• Start after the zero point
initialization is completed.
• Replace the tool.
• Cooling measures are required.
Turn OFF the NC power, or lower
the temperature with an air
conditioner, etc.
• Execute a top search.
• Execute from the restart top
search after resetting.
• If continuing the program restart
operation (automatically/manually
returning to the restart position),
restart is possible from the first
block searched.
• If executing the search again, first
cancel the previous restart search
by resetting. Then execute a
restart search after executing a
top search.
IV – 60