Mitsubishi Electric MELDAS 600M Series Instruction Manual page 416

Table of Contents

Advertisement

6.1 Stored stroke limit I
This is a stroke limit function used by the machine manufacturer. The boundary is set with the
parameters (axis specification parameters "130014 Swot–" and "130015 Swot+"). The outside of the
set boundary is the prohibited range.
When used with the stored stroke limit II function, the confined range designated by the two functions
becomes the moveable valid range.
Downloaded from
ManualsNet.com
CHAPTER 3 MAINTENANCE
6. Setting the Stored Stroke Limit
Machine coordinate system
Machine moveable range
Point 1
-
Setting value
search engine
The following values are set
Point 2
with the coordinate values in the
machine coordinate system.
Point 1: 130014 Swot–
Point 2: 130015 Swot+
+Setting value
III – 30

Advertisement