Mitsubishi Electric MELDAS 600M Series Instruction Manual page 489

Table of Contents

Advertisement

Error No.
PR0625
PR0626
PR0900
PR0901
PR0902
PR0903
PR0920
PR0921
PR0922
PR0990
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 3. Alarm Messages
Message
The general precautions were not
NURBS misc error
observed for the NURBS
command.
The NURBS interpolation
No NURBS spec.
command was issued even
though there are no
specifications.
A normal line direction control
No normal control
command (G40.1/G41.1/G42.1)
was issued even though there are
no such command specifications.
The normal line control axis work
G92 command on
offset rewrite command (G92)
normal axis
was issued during normal line
control.
Normal line control was set for a
Normal axis set as
linear axis.
linear axis
The turning angle at the block
At block joint turn
seams exceeded the limit during
angle over
normal line control.
There is no three-dimensional
No 3DIM coord
coordinate conversion function.
conversion spec.
A G code that cannot be
3DIM coord convert
commanded during the
error
three-dimensional coordinate
conversion modal was issued.
A three-dimensional coordinate
Illegal 3DIM coord
conversion command was issued
convert
in a modal incapable of
three-dimensional coordinate
conversion.
An error occurred during the
Illegal process
program analysis process, and it
became impossible to continue.
search engine
Details
• Check the commands and
modes that cannot be used with
the NURBS interpolation.
• Check the restrictions described
in the Operation Manual.
• Check the specifications.
• Check the specifications.
• Remove the normal line
direction control command from
the program.
• Reconsider the program.
• Set normal line control for a
rotation axis.
• Reconsider the program.
• Check the specifications.
• Reconsider the program.
• Reconsider the program.
• Call the service center with as
many details about the
operation status as possible.