Robot Controller Security Function (Password Setup) - Mitsubishi Electric MELFA FR CR800 Series User Manual

Industrial robots
Table of Contents

Advertisement

15.5. Robot controller security function (Password Setup)

It is possible to forbid access to the robot programs, parameters, and files in the robot controller.
The security function can be achieved by setting a password in the robot controller. The robot controller software
versions where this can be used are as follows.
CR800-D/CR800-R/CR800-Q
CR750-D/CRnD-700 series
CR750-Q/CRnQ-700 series
CRn-500 series
The functions where a password can be set are as follows. It is possible to individually set and release
passwords for access to programs, parameters, and files. The factory default setting of "Password Setup" is "off".
Type
・ Writing the programs.
Program
・ Reading the programs.
・ Copying the programs.
・ Renaming the programs.
・ Deleting the programs.
・ Writing the position data for SQ Direct.
・ Reading the position data for SQ Direct.
・ Initialization of robot programs.
・ File Manager
・ Writing the parameters.
Parameter
・ Position repair function.
・ Restore the origin backup data.
・ Restoring the program information
・ Backup
File
・ Restore
・ Position repair function
Perform registration, change, and the deletion of the password while connected to the robot controller. From the
project tree double-click the target project [Online] -> [Maintenance] -> [Password Setup].
15-367
Table 15-12 Compliant version of this function and controller
Robot Controller
Table 15-13 Function that access is limited.
Limited functions
Software version
All versions
Ver.S3 or later
Ver.R3 or later
Unavailable
Remarks
It is not possible to delete or rename the
file.
It is possible to read the parameters
from the robot controller.
It is not possible to write the revision
parameter created by "Position repair
function" in the robot controller.
15-367

Advertisement

Table of Contents
loading

Table of Contents