11.15.3.

Offline editing

You can edit SQ Direct position data in offline.
Set [R/C-Type] to [CR800-R/CR800-Q/CR750-Q/CRnQ-700] and set [Language] to [MELFA-BASIC
V/MELFA-BASIC VI] in [Edit Project], then [SQ Direct] menu is added to [Offline] menu in project-tree.
You can manage plural SQ Direct files in offline editing.
11.15.3.1.
Creating a new SQ Direct file
Select [Offline] -> [SQ Direct] menu in the project you want to create the new SQ Direct File.
And click a right button with the mouse.
Then right button menu is displayed, and click [New].
Input the SQ Direct file name and click the [OK] button.
Caution
About SQ Direct restoration folder.
SQ Direct Files are managed by each project in the personal computer. The folder named
automatically as follows.
Workspace folder/project name/Program
If you want another folder, use the copy function in program management.