Stop. You have completed this procedure.

NTP-B218 Install the Optical and Ethernet Cards

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Install blank faceplates into empty card slots. Blank faceplates serve three functions: They prevent
Warning
exposure to hazardous voltages and currents inside the ONS 15327 chassis, they eliminate
electromagnetic interference (EMI) that might disrupt other equipment, and they direct the flow of
cooling air through the chassis. Do not operate the system unless all cards and faceplates are in
place.
Install an Ethernet or optical card in Slots 1, 2, 3, or 4
Step 1
a.
b.
c.
d.
Verify that the red FAIL LED illuminates for 20 to 30 seconds.
Step 2
Step 3
Verify that the red FAIL LED blinks for 30 to 45 seconds.
Step 4
Verify that all LEDs blink once and turn off for 5 to 10 seconds.
Verify the ACT LED illuminates.
Step 5
When you log into CTC, verify that the card appears in the correct slot on the CTC node view screen and
Step 6
appears white in node view.
March 2003
"NTP-B218 Install the Optical and Ethernet Cards" procedure on page
This procedure installs the optical cards (OC-3, OC-12, and OC-48) and
Ethernet cards (E10/100-4, G1000-2) in Slots 1 through 4.
None
NTP-B7 Install the Fan-Tray Assembly, page 1-20
NTP-B217 Install the XTCs, page 1-21
Required
Onsite
Retrieve or higher
Open the card ejectors.
Slide the card along the guide rails into the slot.
Close the ejectors.
Lock the cards into place by tightening the ejector locking screws.