At the node, network, or card view, click the Alarms tab.
Step 1
Click the Filter button at the lower-left of the bottom toolbar.
Step 2
The Alarm Filter Dialog box appears, showing the General tab
Figure 6-14 Alarm Filter Dialog Box General Tab
In the General tab Show Severity area, you can choose which alarm severities will show through the
alarm filter and provision a snapshot period during which alarms will appear. To change the alarm
severities shown in the filter, continue with
Step
In the Show Severity area, click the check boxes for the severities [Critical (CR), Major (MJ), Minor
Step 3
(MN), or Not-Alarmed (NA)] you want to be reported at the network level. Leave severity check boxes
deselected (unchecked) to keep them from appearing.
Note
Cisco ONS 15327 Procedure Guide, R4.0
6-28
Use this task change alarm and condition reporting in all network nodes.
None
DLP-B225 Enable Alarm Filtering, page 6-27
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher
4.