NTP-B143 Create an E-Series Hub and Spoke Ethernet Configuration

NTP-B143 Create an E-Series Hub and Spoke Ethernet
Configuration
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Complete the
are already logged in, continue with
Step 2
Complete the
capacity is available (you will create a VLAN during each circuit creation task).
Display the node view.
Step 3
Step 4
Verify that the Ethernet card that will carry the hub and spoke circuit is provisioned for Single-card
EtherSwitch Group. See the
Step 5
Provision and enable the Ethernet ports. See
page
Step 6
Log into the destination spoke node, and repeat Steps
need to verify that the hub node is provisioned for single-card EtherSwitch once.
Step 7
Click the Circuits tab and click Create.
Step 8
In the Create Circuits dialog box, complete the following fields:
Cisco ONS 15327 Procedure Guide, R4.0
5-60
This procedure creates a hub and spoke Ethernet configuration, which is
made up of multiple circuits that share a common endpoint. It does not
apply to E-Series cards in port-mapped mode.
E-Series Ethernet cards must be installed at all Ethernet circuit endpoint
nodes.
NTP-B127 Verify Network Turn Up, page 5-3
As needed
Onsite or remote
Provisioning or higher
"DLP-B60 Log into CTC" task on page 2-23
"DLP-B99 Determine Available VLANs" task on page 5-68
"DLP-B246 Provision E-Series Ethernet Card Mode" task on page
5-69.
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Type—Choose STS.
Size—Choose the circuit size. Valid circuit sizes for an Ethernet single-card circuit are STS-1,
STS-3c, STS6c, and STS12c.
Bidirectional—Leave the default unchanged (checked).
Number of circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable.
State—Choose IS (in service)
Apply to drop ports—Uncheck this check box; states cannot be applied to E-Series ports.
Create cross-connects only (TL1-like)—uncheck this check box; it does not apply to Ethernet
circuits.
Inter-domain (UCP) SLA—If the circuit will travel on a unified control plane (UCP) channel, enter
the service level agreement number. Otherwise, leave the field set to zero.
at the hub node (common endpoint). If you
Step
2.
"DLP-B220 Provision E-Series Ethernet Ports" task on
3
and
4
for the destination Ethernet card. You only
Chapter 5
Create Circuits and VT Tunnels
to verify that sufficient VLAN
March 2003
5-69.