Dlp-B225 Enable Alarm Filtering - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 6
Manage Alarms
As necessary, complete the
Step 4
profile filtering for all network nodes.
Stop. You have completed this procedure.

DLP-B225 Enable Alarm Filtering

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
At the node, network, or card view, click the Alarms tab.
Step 1
Click the Filter tool at the lower-right side of the bottom toolbar.
Step 2
Alarm filtering is enabled if the tool is selected and disabled if the tool is raised (not selected).
Alarm filtering will be enabled in the card, node, and network views of the Alarms tab at the node and
for all other nodes in the network. If, for example, the Alarm Filter tool is enabled in the Alarms tab of
the node view at one node, the Alarms tab in the network view and card view of that node will also show
the tool enabled. All other nodes in the network will also have the tool enabled.
If you filter an alarm in card view, the alarm will still be displayed in node view. In this view, the card
will display the color of the highest-level alarm. The alarm is also shown for the node in the network
view.
Step 3
If you want alarm filtering enabled when you view conditions, repeat Steps
window.
Step 4
If you want alarm filtering enabled when you view alarm history, repeat Steps
window.
Step 5
Return to your originating procedure (NTP).
November 2004
NTP-B168 Enable, Modify, or Disable Alarm Severity Filtering
"DLP-B227 Disable Alarm Filtering" task on page 6-30
Use this task to enable alarm filtering for alarms, conditions, or event
history in all network nodes.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Retrieve or higher
to disable alarm
1
and
2
using the Conditions
1
and
2
Cisco ONS 15327 Procedure Guide, R4.0
using the History
6-27

Advertisement

Table of Contents
loading

Table of Contents