NTP-B225 Switch the Node Timing Reference

DLP-B330 Manual or Force Switch the Node Timing Reference

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Maintenance > Timing tabs. The Timing Source window appears.
Step 1
Click the Reference drop-down menu for the desired Clock, and choose the desired reference.
Step 2
Click the Operation drop-down menu for the desired Clock, and choose one of the following options:
Step 3
Step 4
Click the Apply button.
Step 5
Click Yes in the confirmation dialog.
Step 6
Return to your originating procedure (NTP).

DLP-B331 Clear a Manual or Force Switched Node Timing Reference

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Maintenance > Timing tabs. The Timing Source window appears.
Step 1
Step 2
Find the Clock reference that is currently set to Manual or Force in the Operation menu.
Cisco ONS 15327 Procedure Guide, R4.0
14-28
Manual—This operation commands the NE to switch to the reference you have selected, as long as
the SSM quality of the reference is not less the reference than the node is currently running.
Force—This operation commands the NE to switch to the reference you have selected, regardless of
the SSM quality, as long as the reference is valid.
If the selected timing reference is invalid, a warning dialog appears. Click OK, and the NE remains
on the original timing reference without performing the switch.
If the selected timing reference is an acceptable valid reference, the NE switches to the selected
timing reference.
This task commands the node to switch to the timing reference you have
selected, as long as the synchronization status message (SSM) quality of
the reference is not less than the reference that the node is currently
running.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Maintenance or higher
This task clears a manual or forced node timing reference switch that is
currently in place so that timing will go back to normal timing as defined
by your system configuration.
None
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Maintenance or higher