Ntp-B62 Test Optical Circuits - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 5
Create Circuits and VT Tunnels

NTP-B62 Test Optical Circuits

Purpose
Tools/Equipment
Prerequisite Procedures This procedure assumes you completed facility loopback tests to test the
Required/As Needed
Onsite/Remote
Security Level
If this has not been done, do so now before completing the optical circuit test procedure.
Note
Step 1
Complete the
the circuit(s). If you are already logged in, continue with Step 2.
Step 2
From the View menu choose Go to Network View.
Step 3
Click the Circuits tab.
Set the circuit and circuit ports to Out of Service-Maintenance (OOS_MT):
Step 4
a.
b.
c.
d.
e.
Set up the patch cable at the destination node:
Step 5
a.
b.
Set up the loopback cable at the source node:
Step 6
a.
b.
March 2003
This procedure tests an optical circuit.
Test set capable of optical speeds, appropriate fibers, and attenuators
fibers and cables from the source and destination ONS 15327s to the fiber
distribution panel or the DSX and one of following circuit procedures:
NTP-B188 Create an Automatically Routed Optical Circuit, page 5-39
NTP-B189 Create a Manually Routed Optical Circuit, page 5-43
Required
Onsite
Provisioning or higher
"DLP-B60 Log into CTC" task on page 2-23
Click the circuit you want to test.
From the Tools menu choose Circuits > Set Circuit State.
In the Set Circuit State dialog box, choose OOS-MT from the Target State drop-down menu.
If it is unchecked, check the Apply to drop ports check box.
Click Apply.
Test the patch cable by connecting one end to the test set transmit (TX) port and the other end to the
test receive (RX) port. If the test set does not run error-free, check the cable for damage and check
the test set to make sure it is set up correctly.
Install the loopback cable on the port you are testing. Connect the transmit (TX) to the receive (RX)
of the port being tested.
Test the loopback cable by connecting one end to the test set transmit (TX) port and the other end
to the test receive (RX) port. If the test set does not run error-free, check the cable for damage and
check the test set to make sure it is set up correctly.
At the source node attach the loopback cable to the port you are testing. Connect the test set to the
circuit source port: transmit (TX) port of the test set to the circuit receive (RX) port; test set receive
(RX) port to the circuit transmit (TX) port.
NTP-B62 Test Optical Circuits
at a node on the network where you created
Cisco ONS 15327 Procedure Guide, R4.0
5-51