DLP-B-263 Edit Path Protection Dual Ring Interconnect Circuit Hold-Off Timer

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Click the Circuits tab.
Step 1
Click the UPSR circuit you want to edit, then click the Edit button.
Step 2
In the Edit Circuit window, click the UPSR Selectors tab.
Step 3
Under Hold Off Timer, double-click the cell of the circuit span you want to edit, then type the new
Step 4
hold-off time. The range is 0 to 10,000 ms in increments of 100.
Repeat
Step 5
Click Apply, then close the Edit Circuit window by choosing Close from the File menu.
Step 6
Return to your originating procedure (NTP).
Step 7
Cisco ONS 15327 Procedure Guide, R4.0
8-12
Editing Path Protection Path Selectors
Use this task to change the amount of time a circuit routed on path
protection dual ring interconnect (DRI) topologies are momentarily
prevented from switching. Setting a switch hold off time prevents
unnecessary back and forth switching when a circuit is routed through
multiple path protection selectors.
None
NTP-B44 Provision Path Protection Nodes, page 4-23
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Provisioning or higher
Step 4
as needed to adjust the hold-off timer for each circuit span.
Chapter 8
Manage Circuits
March 2003