NTP-B171 Set Up SNMP

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
If you are already logged in, continue with Step 2.
In node view, click the Provisioning > SNMP tabs.
Step 2
If you want the SNMP agent to accept SNMP SET requests on certain MIBs, click the Allow SNMP Sets
Step 3
check box. If this check box is not selected, SET requests are rejected.
Click the Create button.
Step 4
In the SNMP Traps Destination dialog box
Step 5
Note
March 2003
Bidirectional switching—Check this check box if you want both Tx and Rx signals to switch to the
protect port when a failure occurs to one signal. Leave it unchecked if you want only the failed signal
to switch to the protect port.
Revertive—Check this check box if you want traffic to revert to the working card after failure
conditions stay corrected for the amount of time entered in the Reversion Time field.
Reversion time—If Revertive is checked, choose the reversion time from the pull-down menu. The
range is 0.5 to 12.0 minutes. The default is 5.0 minutes. Reversion time is the amount of time that
will elapse before the traffic reverts to the working card. Traffic can revert when conditions causing
the switch are cleared.
This procedure provisions the SNMP parameters so that you can use
SNMP management software with the ONS 15327.
None
NTP-B24 Verify Card Installation, page 3-2
As needed
Onsite or remote
Provisioning or higher
"DLP-B60 Log into CTC" task on page 2-23
IP Address—Type the IP address of your network management system. If the node you are logged
into is an ENE, type the IP address of the ONS 15327 GNE.
Community Name—Type the SNMP community name. For a description of SNMP community
names, refer to the SNMP information in the Cisco ONS 15327 Reference Manual.
The community name is a form of authentication and access control. The community name
assigned to the ONS 15327 is case-sensitive and must match the community name of the NMS.
UDP Port—The default UDP port for SNMP is 162. If the node is an ENE in a proxy server network,
the UDP port must be set to the GNE's SNMP relay port which is 391.
at the node where you want to set up SNMP.
(Figure
3-3), complete the following:
Cisco ONS 15327 Procedure Guide, R4.0
NTP-B171 Set Up SNMP
3-21