NTP-B28 Set Up Timing

DLP-B68 Provision the IIOP Listener Port on the CTC Computer

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
In node view, from the Edit menu choose Preferences.
On the Preferences dialog box, click the Firewall tab.
Step 2
Under CTC CORBA (IIOP) Listener Port, choose a listener port option:
Step 3
Click Apply. A warning is displayed telling you that the port change will apply during the next CTC
Step 4
login.
Step 5
Click OK.
On the Preferences dialog box, click OK. A warning appears telling you that the port change will apply
Step 6
during the next CTC login.
To access the ONS 15327 using the IIOP port, log out of CTC (from the File menu, select Exit).
Step 7
Log into CTC. See the
Step 8
Return to your originating procedure (NTP).
Step 9
NTP-B28 Set Up Timing
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Log into the ONS 15327 node where you want to set up timing. See the
Step 1
on page 2-23
Cisco ONS 15327 Procedure Guide, R4.0
3-16
This task selects the IIOP listener port on CTC.
IIOP listener port number provided by your LAN or firewall administrator
DLP-B60 Log into CTC, page 2-23
As needed
Onsite or remote
Provisioning or higher
Default - Variable—Select this option if the ONS 15327s are on the same side of the firewall as the
CTC computer or if no firewall is used (default). This option sets the CTC listener port to Port
57790. It can be used for access through a firewall if Port 57790 is open.
Standard Constant—Select this option to use Port 683, the CORBA default port number, as the CTC
computer listener port.
Other Constant—If Port 683 is not used, enter the IIOP port provided by your administrator. The
port cannot be set to any port listed in
"DLP-B60 Log into CTC" task on page 2-23
This procedure provisions the ONS 15327 timing.
None
NTP-B24 Verify Card Installation, page 3-2
Required
Onsite or remote
Provisioning or higher
for instructions. If you are already logged in, continue with Step 2.