Ntp-B148 Create A Manual Cross-Connect For A G-Series Or An E-Series In Port-Mapped Mode - Cisco ONS 15327 Procedure Manual

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 5
Create Circuits and VT Tunnels
Note
Complete the
Step 13
Stop. You have completed this procedure.
NTP-B148 Create a Manual Cross-Connect for a G-Series or an
E-Series in Port-Mapped Mode
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
In this procedure, cross-connect refers to a circuit connection created within the same node between the
Ethernet card and an OC-N card connected to third-party equipment. You create cross-connects at the
source and destination nodes so an Ethernet circuit can be routed from source to destination across
third-party equipment.
Complete the
Step 1
cross-connect. If you are already logged in, continue with
If you are provisioning an E-Series card, verify that the Ethernet card that will carry the circuit is
Step 2
provisioned for port-mapped mode. See the
on page
Click the Circuits tab and click Create.
Step 3
In the Create Circuits dialog box, complete the following fields:
Step 4
March 2003

NTP-B148 Create a Manual Cross-Connect for a G-Series or an E-Series in Port-Mapped Mode

To change the capacity of a G-Series circuit, you must delete the original circuit and reprovision
a new larger circuit.
"NTP-B149 Test G-Series Circuits" procedure on page
This procedure creates a manual cross-connect between a G-Series
Ethernet card or an E-Series card in port-mapped mode and an OC-N card
connected to non-ONS equipment.
A G-Series or E-Series card must be installed at the circuit source node.
NTP-B127 Verify Network Turn Up, page 5-3
As needed
Onsite or remote
Provisioning or higher
"DLP-B60 Log into CTC" task on page 2-23
5-69.
Name—Assign a name to the source cross-connect. The name can be alphanumeric and up to 48
characters (including spaces). Circuit names should be 44 characters or less if you want the ability
to create monitor circuits. If you leave the field blank, CTC assigns a default name to the source
cross-connect.
Type—Choose STS.
Size—Choose the size of the circuit that will be carried by the cross-connect. Valid sizes for a
G-Series circuit are STS-1, STS-3c, STS-6c, STS-9c, STS-12c, STS-24c, and STS-48c. For an
E-Series in port-mapped mode, valid sizes are STS-1, STS-3c, STS-6c, and STS-12c.
Bidirectional—Leave the default unchanged (checked).
Number of circuits—Leave the default unchanged (1).
5-78.
at a node where you will create the
Step
2.
"DLP-B246 Provision E-Series Ethernet Card Mode" task
Cisco ONS 15327 Procedure Guide, R4.0
5-75