7.5.2

Connecting serial communication module (Q, L Series)

■1. [Intelligent function module switch setting] on GX Developer
[The intelligent function module switch setting] on GX Developer is not necessary. (When no [intelligent function
module switch setting] is made, the module runs in the GX Developer connection mode.)
A module can be also connected to a GOT by making the following [intelligent function module switch setting] on GX
Developer.
(1) When connecting to the CH1 side
Switch
No.
Switch 1
Switch 2
Switch 5
7 - 36
7.5 PLC Side Setting
POINT
POINT
POINT
(1) Serial communication module (Q, L Series)
For details of the serial communication module (Q, L Series), refer to the following manual.
Q Corresponding Serial Communication Module User's Manual (Basic)
MELSEC-L Serial Communication Module User's Manual (Basic)
(2) Modem interface module
For details of the modem interface module, refer to the following manual.
Modem Interface Module User's Manual
Bit
Position
Specified value
b0
OFF
b1
OFF
b2
OFF
b3
OFF
b4
OFF
b5
OFF
b6
OFF
b7
OFF
b8 to b15
Description
Operation setting
Data Bit
Parity Bit
CH1
Even/Odd parity
transmission
Stop bit
*1
settings
Sum check code
Write during RUN
Setting modifica-tions
*2
CH1 transmission speed setting
CH1 Communication protocol setting
Station number setting
Set value
(Operates according to
the GOT side
0000H
specifications.)
GX Developer
0000H
connection
0th station
0000H
*3