Setting item
Ethernet IP address 1
(Built-in Ethernet)
Ethernet IP address 2
(Built-in Ethernet)
Ethernet IP address 3
(Built-in Ethernet)
Ethernet IP address 4
(Built-in Ethernet)
Subnet mask 1
Subnet mask 2
Subnet mask 3
Subnet mask 4
Ethernet IP filter address 1
Ethernet IP filter address 2
Ethernet IP filter address 3
Ethernet IP filter address 4
Ethernet IP filter address 2
range specification
Ethernet IP filter address 3
range specification
Ethernet IP filter address 4
range specification
Ethernet command source
selection IP address 1
Ethernet command source
selection IP address 2
Ethernet command source
selection IP address 3
Ethernet command source
selection IP address 4
Ethernet command source
selection IP address 3
range specification
Ethernet command source
selection IP address 4
range specification
Keepalive time
*1
Setting items are parameter names described in the manual of FREQROL-A800/F800-E series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change the parameters on the inverter to correspond with the GOT settings.
*3
Inverter default values (No need to change)
*4
Since the default value of the inverter side is the "0:disable", please change when using the sequence function [1] or [2].
14 - 52
14.3 Ethernet Connection
Parameter
*1
No.
Pr.1434
*2
Pr.1435
*2
Pr.1436
*2
Pr.1437
*2
*2
Pr.1438
*2
Pr.1439
*2
Pr.1440
*2
Pr.1441
Pr.1442
Pr.1443
Pr.1444
Pr.1445
Pr.1446
Pr.1447
Pr.1448
Pr.1449
Pr.1450
Pr.1451
Pr.1452
Pr.1453
Pr.1454
Pr.1455
Set value
0 to 255
**** .**** .**** .**** .
0 to 255
**** .**** .**** .**** .
0 to 255
**** .**** .**** .**** .
Specify the IP address range of the network devices permitted for
0 to 255,
connection.
9999
This function is invalid if Pr. 1442 to 1445 are set to "0".
0 to 255
**** .**** .**** .**** .
0 to 255,
Specify the IP address range of the network devices that issue the operation
9999
rights during Ethernet communication.
*3
3600s
Contents of setting
Set the first octet with Pr .1434.
Set the second octet with Pr .1435.
Set the third octet with Pr .1436.
Set the fourth octet with Pr .1437.
Set the first octet with Pr .1438.
Set the second octet with Pr .1439.
Set the third octet with Pr .1440.
Set the fourth octet with Pr .1441.
Set the first octet with Pr .1442.
Set the second octet with Pr .1443.
Set the third octet with Pr .1444.
Set the fourth octet with Pr .1445.
Set the first octet with Pr .1449.
Set the second octet with Pr .1450.
Set the third octet with Pr .1451.
Set the fourth octet with Pr .1452.
-