17.7.4

Ethernet connection

■1. Via network system
GOT with Ethernet communication cannot access the CNCs in another network via the CNC (network module,
Ethernet module, etc.).
■2. When connecting to multiple GOTs
When connecting two or more GOTs in the Ethernet network, set each [PLC No.] to the GOT.
■3. When connecting to the multiple network equipment (including GOT) in a segment
By increasing the network load, the transmission speed between the GOT and CNC may be reduced.
The following actions may improve the communication performance.
• Using a switching hub
• More high speed by 100BASE-TX (100Mbps)
• Reduction of the monitoring points on GOT
■4. Ethernet cable connection
Ethernet cable is so susceptible to noise that you should wire power cables and electric supply cables separately. And
you need to attach a ferrite core (attachment) on the control unit side.
For details of the Ethernet cable connection, refer to the following
■5. Version of CNC
For MELDAS C6/C64, use NC system software version D0 or later.
17 - 26
17.7 Precautions
17.4.1 Setting communication interface (Controller Setting)
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373 IX Connection Function with
GOT
LED1
Ferrite
core
Ethernet
FG cable for Ethernet
1 turn
GOT
Ferrite core