Mitsubishi Electric GOT2000 Series Connection Manual page 364

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■4. [Controller Setting] and [Ethernet] of GT Designer3
(1) Controller setting
GOT Net No.
GOT Station
GOT Standard Ethernet Setting
GOT Communication Port No.
Retry
Startup Time
Timeout Time
Delay Time
*1
(2) GOT Standard Ethernet Setting
GOT IP Address
Subnet Mask
Default Gateway
Peripheral Communication Port No.
Transparent Port No.
(3) Ethernet setting
Ethernet Setting No.1
*1
*2
*3
*4
(4) Routing parameter setting
Transfer Network No.
Relay Network No.
Relay Station No.
*1
*2
*3
5 - 98
5.4 PLC Side Setting
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
5.3.1 Setting communication interface (Controller Setting)
Item
Set the GOT network No. according to the third octet (network No.) of the Ethernet adapter module IP address.
Item
Item
Host
N/W No.
PC No.
Type
IP address
Port No.
Communication
Set according to the third octet (network No.) of the Ethernet adapter module IP address.
Set according to the fourth octet (PC No.) of the Ethernet adapter module IP address.
Set according to the Ethernet adapter module IP address.
The following [Port No.] and [Communication format] can also be set.
[Port No.]: 5002
[Communication]: TCP
Item
Set the same value as the Ethernet adapter module network No.
Set according to the third octet (network No.) of the Ethernet adapter module IP address.
Set according to the fourth octet (PC No.) of the Ethernet adapter module IP address.
*4
*4
Set value (Use default value)
*1
3
1
192.168.3.18
5001
3 times
3 sec
3 sec
0ms
Set value (Use default value)
192.168.3.18
255.255.255.0
0.0.0.0
5015
5014
Set value
*
*1
3
*2
30
NZ2GF-ETB
*3
192.168.3.30
5001
UDP
Set value
*1
1
*2
3
*3
30