Mitsubishi Electric GOT2000 Series Connection Manual page 928

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(3) Ethernet setting
Ethernet setting No.1
■4. Confirming communication state of CRnD-700
(1) When using the Command Prompt of Windows.
Execute a Ping command at the Command Prompt of Windows.
(a)
When normal communication
C:\>Ping 192.168.0.19
Reply from 192.168.0.19: bytes=32 time<1ms TTL=64
(b)
When abnormal communication
C:\>Ping 192.168.0.19
Request timed out.
(2) When abnormal communication
At abnormal communication, check the followings and execute the Ping command again.
• Cable connecting condition
• Parameter settings
• Operation state of the CRnD-700. (faulty or not)
• The IP address of the CRnD-700 specified for the Ping command.
16 - 10
16.4 Robot controller Side Settings
Item
Host
N/W No.
PLC No.
Unit Type
IP address
Port No.
Communication
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT Designer3, refer to the following.
16.3.1 Setting communication interface (Controller Setting)
Set value
*
1
2
CRnD-700
192.168.0.19
5001 (fixed)
UDP (fixed)