Ethernet Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

16.3.4

Ethernet setting

Item
Host
The host is displayed. (The host is indicated with an asterisk (*))
N/W No.
Set the network No. of the connected Ethernet module. (Default: blank)
*2
Set the station No. of the connected Ethernet module. (Default: blank)
PLC No.
Set the type of the connected Ethernet module.
*1
Unit Type
CRnD-700, CR800
IP address
Set the IP address of the connected Ethernet module. (Default: blank)
The port No. and communication can be set differs depending on the [Unit Type].
<CR800>
Port No./Communication
<CRnD-700>
*1
Selected from [CRnD-700] and [CR800] for [Controller Type].
*2
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
16.3.2 Communication detail settings
POINT
POINT
POINT
(1) Example of [Ethernet]
(2) Communication interface setting by Utility
(3) Precedence in communication settings
Description
• When the port No. is [5006], the communication is [UDP (fixed)].
• When the port No. is [5007], the communication is [TCP (fixed)].
• Port No. can be set only [5001], communication is [UDP (fixed)].
For examples of [Ethernet], refer to the following.
16.4 Robot controller Side Settings
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
GOT2000 Series User's Manual (Utility)
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
Range
1 to 239
1 to 64
CRnD-700, CR800
0.0.0.0 to 255.255.255.255
16.3 GOT Side Settings
16
16 - 5