16.3.4
Ethernet setting
Item
Host
The host is displayed. (The host is indicated with an asterisk (*))
N/W No.
Set the network No. of the connected Ethernet module. (Default: blank)
*2
Set the station No. of the connected Ethernet module. (Default: blank)
PLC No.
Set the type of the connected Ethernet module.
*1
Unit Type
CRnD-700, CR800
IP address
Set the IP address of the connected Ethernet module. (Default: blank)
The port No. and communication can be set differs depending on the [Unit Type].
<CR800>
Port No./Communication
<CRnD-700>
*1
Selected from [CRnD-700] and [CR800] for [Controller Type].
*2
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
➠
16.3.2 Communication detail settings
POINT
POINT
POINT
(1) Example of [Ethernet]
(2) Communication interface setting by Utility
(3) Precedence in communication settings
Description
• When the port No. is [5006], the communication is [UDP (fixed)].
• When the port No. is [5007], the communication is [TCP (fixed)].
• Port No. can be set only [5001], communication is [UDP (fixed)].
For examples of [Ethernet], refer to the following.
➠
16.4 Robot controller Side Settings
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
➠
GOT2000 Series User's Manual (Utility)
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
Range
―
1 to 239
1 to 64
CRnD-700, CR800
0.0.0.0 to 255.255.255.255
16.3 GOT Side Settings
16