12.2.3

Connecting with CC-Link Ver.1/Ver.2 compatibles mixed

QCPU
PLC
Model name
CC-Link module
MELSEC iQ-R
Series
Motion controller
CPU (MELSEC iQ-
R Series)
C Controller
RJ61BT11
module (MELSEC
iQ-R Series)
CNC C80
CR800-
R(R16RTCPU)
MELSEC-Q
(Q mode)
C Controller
module
(Q Series)
QJ61BT11N
Motion controller
CPU (Q Series)
CNC C70
Robot controller
(CRnQ-700)
MELSEC iQ-F
FX3U-16CCL-M
*6
series
FX5-CCL-MS
*7
MELSEC-FX
*1
For the system configuration of the CC-Link module, refer to the following manual.
CC-Link System Master/Local Module User's Manual QJ61BT11N
*2
For the specifications and inquiries of the CC-Link dedicated cable, refer to the following.
CC-Link Partner Association's home page: http://www.cc-link.org/
*3
The maximum overall extension cable length and the length between stations vary depending on the cable type to be used and
the transmission speed.
For details, refer to the following manual.
CC-Link System Master/Local Module User's Manual QJ61BT11N
FX3U-16CCL-M USER'S MANUAL
*4
Specify Ver.2 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
12.3.1 Setting communication interface (Controller Setting)
*5
Specify Ver.1 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
12.3.1 Setting communication interface (Controller Setting)
*6
When using an FX3U-16CCL-M with the MELSEC iQ-F series, bus conversion module (FX5-CNV-BUS or FX5-CNV-BUSC) is
required.
*7
MELSEC-FX do not support FX5-CCL-MS.
*8
GT25-W, GT2505-V does not support the option device.
CC-Link
module
Connection cable
Connection cable
Communication
*1
Cable model
type
CC-Link dedicated
cable
CC-Link (Ver.2)
*2
CC-Link dedicated
cable
CC-Link (Ver.1)
*2
CC-Link dedicated
cable
CC-Link (Ver.2)
*2
CC-Link dedicated
cable
CC-Link (Ver.1)
*2
CC-Link dedicated
cable
CC-Link (Ver.2)
*2
CC-Link dedicated
cable
CC-Link (Ver.1)
*2
GOT
GOT
Max.
*8
Option device
distance
GT15-J61BT13
*3
*4
GT15-J61BT13
*3
*5
GT15-J61BT13
*3
*4
GT15-J61BT13
*3
*5
*3
GT15-J61BT13
*4
*3
12.2 System Configuration
Communication driver
CC-Link Ver2(ID)
Number of
connectable
Model
equipment
26 GOTs
8 GOTs
12
12 - 11