The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
*2
A straight cable is available.
When connecting CPU and GOT directly with Ethernet cable, remember that the by cross cable is available.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of Built-in Ethernet port QCPU, refer to the following manual.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
*5
Select [QnUD(P)V/QnUDEH] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
5.3.4 Ethernet setting
*6
For the system configuration of Built-in Ethernet port LCPU, refer to the following manual.
MELSEC-L CPU Module User's Manual (Built-In Ethernet Function)
*7
Select [LCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
5.3.4 Ethernet setting
*8
Select [RCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
5.3.3 GOT Ethernet Setting
*9
For the system configuration of Built-in Ethernet port RCPU, refer to the following manual.
MELSEC iQ-R CPU Module User's Manual (Built-In Ethernet Function)
*10
Select [FX5CPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
5.3.3 GOT Ethernet Setting
*11
For the system configuration of MELSEC iQ-F series, refer to the following manual.
MELSEC iQ-F User's Manual
*12
By the controller type of the C Controller module (Q Series) and an operation mode, It's different in number of connectable GOTs.
Controller Type
Q12DCCPU-V
Q24DHCCPU-V/VG/LS
*13
GT25-W, GT2505-V does not support the option device.
Operation mode
standard monitor mode
Expansion mode
-
5.2 System Configuration
Number of connectable GOTs
1
16
16
5 - 15
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents