Ethernet Circuit Configurations

Figure 9-14 A Hub and spoke Ethernet circuit

Access router
Access router
Access router
Procedure: Provision a Hub and Spoke Ethernet Circuit
Display CTC for one of the ONS 15327 Ethernet circuit endpoints.
Step 1
Step 2
Double-click the Ethernet card that will create the circuit.
Click the Provisioning > Card tabs.
Step 3
Under Card Mode, check the Single-card EtherSwitch check box.
Step 4
If Single-card EtherSwitch is not checked, check it and click Apply.
Navigate to the other ONS 15327 endpoint and repeat Steps 2–4.
Step 5
Display the node view or network view.
Step 6
Click the Circuits tab and click Create.
Step 7
The Circuit Creation (Circuit Attributes) dialog box appears.
Step 8
In the Name field, type a name for the circuit.
From the Type pull-down menu, choose STS.
Step 9
Note
Choose the size of the circuit from the Size pull-down menu.
Step 10
Verify that the Bidirectional check box is checked and click Next.
Step 11
The Circuit Creation (Circuit Source) dialog box appears.
From the Node menu, choose the circuit source.
Step 12
Either end node can be the circuit source.
Cisco ONS 15327 User Documentation, R3.3
9-14
ONS
Node
Access router
The types VT and VT Tunnel do not apply to Ethernet circuits.
Backbone router
ONS
Node
Access router
Access router
ONS
Node
Access router
Chapter 9
Ethernet Operation
Access router
Access router
ONS
Node
Access router
SONET
Ethernet
June 2002

Advertisement

Table of Contents
loading

Table of Contents