LEDs
The illustration below shows the LEDs on the computer unit:
xx1300000857
Description
POWER
(green)
DISC-Act
(yellow)
STATUS
(red/green)
NS
(red/green)
MS
(red/green)
For information about the LEDs on the AnybusCC slave fieldbus adapter and the
PCIExpress master/slave fieldbus board, see the corresponding fieldbus manual.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Significance
Normal startup:
OFF, During a normal startup the LED is off until COM Express
module inside the computer unit is started.
SOLID ON, After completion of startup LED is solid on.
Failure during startup (off between blinks). One to four short blinks, one
second off. This is repeated until power off.
Internal fail of power, FPGA, and/or the COM Express module.
Replace the computer unit.
Power failure during runtime (fast flashing between blinks). One to five
blinks, 20 fast flashing blinks. This is repeated until power off.
Temporary voltage drop, cycle the power to the controller.
Check the power supply voltage to the computer unit.
Replace the computer unit.
(Disc activity.)
Indicates that the computer is writing to the SD-card.
Startup sequence:
1 SOLID RED, loading bootloader.
2 FLASHING RED, loading image.
3 FLASHING GREEN, loading RobotWare.
4 SOLID GREEN, system ready.
Fault indication:
SOLID RED forever, check the SD-card.
FLASHING RED forever, check the SD-card.
FLASHING GREEN forever, view error messages on FlexPendant
or CONSOLE.
(Network Status)
Not used.
(Module Status)
Not used.
© Copyright 2005-2018 ABB. All rights reserved.
4 Troubleshooting by unit
4.5 Troubleshooting the computer unit
Continued
69