5 Troubleshooting by event log
5.10 11 xxxx
Continued
The value arg for sensordatatype at array index arg is to big
for the sensordatatype arg
arg.
Recommended actions
Change the value in sensorVarData.
110186, Invalid sensordatatype in Data
Description
Task: arg.
The value arg for sensordatatype at array index arg is not valid
for configured device
arg.
Recommended actions
Change sensordatatype value to a valid value 0 or 1.
110203, Application error
Description
Task: arg
The maximum program number, 'DA_PROG_MAX' is above the
num data type limit.
Current value: arg
Consequences
The maximum configured program number will not be set.
Probable causes
The specified program number arg is above the maximum
integer value for the num data type, max value 8388608.
Recommended actions
Check the program.
110204, Application error
Description
Task: arg
Any return code other than DAOK is rejected from arg
Recommended actions
110205, Application error
Description
Task: arg
Forward sequence jumping is not allowed.
Recommended actions
Check the program sequence.
Continues on next page
460
110206, Application error
Description
Task: arg
Missing I/O-signal arg.
Recommended actions
Check the I/O configuration.
110207, Application error
Description
Task: arg
Process number arg of application arg was already installed.
Recommended actions
110208, Application error
Description
Task: arg
Number arg is not a valid start number.
Recommended actions
110209, Application error
Description
Task: arg
The user hook arg is not a valid sequence entry.
Recommended actions
Check the program sequence.
110210, Application error
Description
Task: arg
The program number arg is above the num data type limit.
Consequences
The program number will not be set.
Probable causes
The specified program number arg is above the maximum
integer value for the num data type, max value 8388608.
Recommended actions
Check the program.
110211, Application error
Description
Task: arg
The instruction arg reported a fatal error.