5 Troubleshooting by event log
5.5 3 xxxx
Continued
32568, Axis computer firmware file error
Description
The file arg, required to upgrade an axis computer's firmware,
is not usable because it failed the integrity check.
Consequences
The required upgrade of the axis computer firmware is not
performed.
Probable causes
The firmware file is corrupt.
Recommended actions
Reinstall the system.
32569, Corrupt axis computer hardware
Description
In drive module arg, the axis computer flash memory has a
corrupt content.
Recommended actions
Retry again by restarting the controller using the main power
switch. If the problem remains then replace the axis computer.
32570, Firmware re-flash started
Description
A required update of the arg firmware has started. Replacing
old firmware version: [arg].
Recommended actions
Wait for the re-flash to complete.
32571, Firmware re-flash completed
Description
The update of arg firmware has completed successfully. New
version: [arg]. Internal code:[arg]
32572, Firmware re-flash failed
Description
The upgrade of arg firmware failed.
Current version:arg. Internal error code:arg.
Recommended actions
Check other hardware eventlog messages for detailed
explanation of the error condition. Reinstall the system.
32573, Unable to download firmware file
Description
The firmware file arg is not found. Internal error code:arg.
Continues on next page
164
Recommended actions
Reinstall the system.
32574, Corrupt axis computer hardware
Description
The arg flash memory has a corrupt content. Internal error
code:arg.
Recommended actions
Check other hardware event log messages for detailed
explanation of the error condition. Restart the controller. If
failure occurs again, replace the axis computer.
32575, Found no axis computer board
Description
System failed to detect any connected axis computer.
Recommended actions
Check system for axis computer board. Check Ethernet cables
between the main computer and the axis computer. Restart the
controller.
32576, Axis firmware: No communication
Description
The system failed to communicate with axis board arg when
trying to check the firmware version.
Consequences
The system is unable to check and if necessary upgrade the
firmware in the affected axis computer.
Recommended actions
Check system for axis computer board. Check Ethernet cables
between the main computer and the axis computer. Restart the
controller.
32577, Axis computer hardware data error
Description
In drive module arg, the axis computer has corrupt information
stored on the unit.
Consequences
The system goes to system failure state.
Probable causes
The integrity check of the axis computer information stored on
the unit has failed.
© Copyright 2005-2018 ABB. All rights reserved.