Recommended actions
Modify the configuration of the I/O system (by reducing the
number of I/O signals specified in the additional option
configuration) so that the maximum limit is not exceeded.
71473, DeviceNet network scan result
Description
Address___Vendor_ID___Product_code___Device_name__
arg
71476, DeviceNet firmware file not found
Description
The DeviceNet firmware file arg was not found or is not
readable.
The board firmware may be out of date.
Recommended actions
Reinstall the system.
71477, Invalid connection size for EtherNet/IP
adapter
Description
The adapter arg is configured with invalid input and/or output
size.
Consequences
No communication with the adapter is possible.
Recommended actions
Correct the input size to arg and the output size to arg for the
adapter in the I/O configuration.
71478, Invalid input or output assembly for
EtherNet/IP adapter
Description
The adapter arg has invalid input and/or output assembly.
Consequences
No communication with the adapter is possible.
Recommended actions
Correct the input/output assembly for the adapter in the I/O
configuration.
71479, Invalid configuration assembly for
EtherNet/IP I/O device
Description
The adapter arg has invalid configuration assembly.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Consequences
No communication with the adapter is possible.
Recommended actions
Correct the configuration assembly for the adapter in the I/O
configuration.
71480, Adapter occupied by another scanner
Description
It is not possible to connect to the adapter arg because it
already has an active connection.
Consequences
No communication with the adapter arg is possible as long as
the adapter is occupied by another scanner.
Recommended actions
Release the connection from the other scanner to the adapter
arg or change the address.
71481, PROFINET configuration file error
Description
The PROFINET configuration file arg could not be found or
opened.
Consequences
The configuration file is needed to be able to use the I/O devices
defined on the arg network.
Recommended actions
Make sure the file exists. Make sure that the configuration file
is placed in the HOME directory of your current system if
filename without path is used.
71482, PROFINET network configuration changed
Description
I/O configuration for the network arg has been changed by an
external configuration tool or a connecting controller.
The following values have been changed:
IP Address: arg.
Subnet mask: arg.
Gateway address: arg.
71483, PROFINET identification request received
Description
A PROFINET identification request has been received from an
external configuration tool.
The MAC address on the arg network is arg.