Advertisement

5 Troubleshooting by event log
5.10 11 xxxx
Continued
111424, Partdata not found for PLC code
Description
No matching partdata found in task arg for PLC code arg
Recommended actions
Create partdata with matching plc code.
111425, Menudata not found for PLC code
Description
No matching menudata found in task arg for PLC code arg
Recommended actions
Create menudata with matching plc code.
111426, Not valid task state for menudata
Description
The state of task arg should be at safe or at service when
running selected menudata.
111427, Not valid station for menudata
Description
Current station (arg) in task arg does not match valid station
arg in menudata
111428, Not valid user level for menudata
Description
Not valid menudata. Current user level arg does not match
minimum user level arg defined in menudata
111429, Part execution error
Description
Part procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the
partdata to an existing procedure.
111430, Menu execution error
Description
Menu procedure: arg in task arg does not exist
Recommended actions
Create the procedure arg or change the procedure in the menu
to an existing procedure.
Continues on next page
500
111431, Timeout during handshaking
Description
Timeout during handshaking in task arg.
Probable causes
The configured signal run_part_signal_in or run_menu_signal_in
wasn't set to 0 within configured timeout (arg seconds) after
the configured signal run_ack_out was set to 1.
Recommended actions
Make sure to reset configured signal run_part_signal_in or
run_menu_signal_in after configured signal run_ack_out is set
to 1.
111432, Not valid plc code in task
Description
Not valid plc code in task arg.
Probable causes
The configured group signal plc_cmd_group_in has a not valid
value arg.
Values in the range of 1-99 is reserved for error codes.
Recommended actions
Make sure requests are higher than 99.
111433, Next station configuration error
Description
PROC configuration for next_stn_arg_signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure next_stn_arg_signal_in to ensure that orders for
station arg will be executed.
111434, At station configuration error
Description
PROC configuration for at_stn_arg_signal_in not configured.
Consequences
Order for station arg may not be executed.
Recommended actions
Configure at_stn_arg_signal_in to ensure that orders for station
arg will be executed.
111501, BullsEye Text Error
Description
BullsEye could not access text.