Xxxx - ABB IRC5 Operating Manual

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log

5.5 3 xxxx

5.5 3 xxxx
31810, DeviceNet master/slave board is missing
Description
The DeviceNet master/slave board does not work.
Consequences
No communication on the DeviceNet network is possible.
Probable causes
The DeviceNet master/slave board is either malfunctioning or
missing.
Recommended actions
Make sure a DeviceNet master/slave board is installed. Replace
the board if faulty.
31910, PROFIBUS master board is missing
Description
The PROFIBUS master board does not work.
Consequences
No communication on the Profibus is possible.
Probable causes
The PROFIBUS master board is either malfunctioning or
missing.
Recommended actions
Make sure a PROFIBUS master board is installed. Replace the
board if faulty.
31911, Profibus board update error
Description
The RobotWare software was not able to download new driver
software to the PROFIBUS master board. The arg channel (ch
arg) of the Profibus board could not be programmed. Internal
error code:arg.
Consequences
No communication on the Profibus is possible.
Probable causes
The RobotWare software may be corrupt or the board hardware
may be malfunctioning.
Recommended actions
Restart the controller to reattempt downloading the software.
Reinstall the present system files. Create and run a new system
to download the driver software. Replace the board if faulty.
Continues on next page
160
31912, PROFIBUS master board failure
Description
The PROFIBUS master board did not start up correctly.
Consequences
No communication on the Profibus is possible.
Probable causes
The PROFIBUS master board hardware may be malfunctioning.
Recommended actions
Restart the controller. Replace the PROFIBUS master board if
faulty.
31913, PROFIBUS master board internal error
Description
The PROFIBUS master board reported internal error arg.
Consequences
No communication on the PROFIBUS network is possible.
Probable causes
The PROFIBUS master board hardware may be malfunctioning.
Recommended actions
Restart the controller. Replace the PROFIBUS master board if
faulty.
31914, PROFIBUS network startup error
Description
PROFIBUS network startup error arg. Check cabling, terminators
and modules then restart.
Recommended actions
31915, PROFIBUS network error
Description
PROFIBUS master network error.
Internal error
Error code arg.
Consequences
Certain expected associated errors may be delayed.
Probable causes
Faulty PROFIBUS cabling, terminators and/or module(s).
Duplicated PROFIBUS addresses.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA

Hide quick links:

Advertisement

Table of Contents
loading